|
CAGE'N BIRD
|
HYGROMETERS & THERMOMETERS
ccurate measuring devises are important when incubating and hand-feeding. There are many instruments available which will measure temperature and humidity levels. NOTE: Handfeeding formula can safely be fed at approximately 103° to 105°F. never more then 110°F and not less then 100°F, for most species. An accurate formula thermometer should be used to measure formula temperature when handfeeding. When formula temperature is routinely measured crop burn and crop stasis can be prevented
Wet bulb Thermometer - checking humidity directly
.............................................#HT-SDT-BP $42.00**
Spot-Check Digital Thermometer
Liquid in Glass Thermometer
When disaster strikes and your developing chicks are threatened by any of the everyday problems listed above, the most important protection is for the breeder to be quickly made aware of the crisis. If power failure happens in the middle of the night, the damage will have been done before morning, but in most cases action can be taken to protect the eggs, provided the user is alerted. The Brinsea temperature alarm module offers immediate warning of change in temperature within an incubator. It relies on independent detection of temperature and includes an internal battery backup to allow the alarm to continue to sound in the event of a mains power failure. The high and low temperature limits are adjustable and in most cases the alarm can be set to go off if the temperature varies by 1.0ºF (0.5°C). The module is available in two versions: The T100 for fitting to Brinsea Octagon 100 or 250 incubators, only. The T100 has the additional feature of regulating temperature in the case of a failure of the main temperature control which could otherwise lead to uncontrolled temperature rise. In this case the T100 alarm will trigger and the heaters in the Octagon 100 series incubator are switched off. As the temperature then falls below the upper limit the heaters are switched on again and so reasonable temperature control is maintained. The T20 can be fitted to any incubator or brooder. The T20 can be used to warn of temperature variation in any environment within its operating range of 77 - 104ºF range (25 - 40°C). The T20 simply requires its sensor to be inserted into the enclosure through a hole of about ¼ inch (6mm) diameter. Both the high and low limits are easily adjustable with screwdriver operated trimmers. The system is flexible and allows the user to set the alarm sound if the temperature deviates by +1.0ºF or -3.0ºF (for example) from any temperature within 77 - 104ºF range. A 'Silence Alarm' feature allows the sounder to be de-activated for about 10 minutes - useful when opening the incubator to check eggs. The sounder automatically resets after 10 minutes so there is no danger of the sounder being left inoperative by accident. The internal
battery backup allows the alarm to continue warning of a mains failure for
several hours. The backup battery is automatically recharged when reconnected to
the mains. To Place an Internet Order Use Our Order Formor
|
|
|
Telephone:
337-394-6683